CTI Certificated Counter Flow Cloosed Cooling Water Tower for Screw Chiller

US$1,000.00 - 15,000.00 1 Piece (MOQ)
Port:
Shanghai, China
Production Capacity:
100sets/Month
Payment Terms:
L/C, T/T, Western Union, Paypal

Last Login Date:

Sep 02, 2025

Main Products:

Cooling Tower, Water Chiller, Heat Pump, Cooling System, Thermal Fluid Heater, SMC Water Tank

Find Similar Products
US$2,300.00-13,100.00
1 Piece (MOQ)

Product Description

Company Info

Basic Info.

Model NO.
GBN-T
Cooling Method
Counter Flow
Ventilation Mode
Mechanical Ventilation
Material
Metal
Air Contact Form
Wet
Air Contact Way
Closed
Tower Shape
Square
Noise Level
Ultra Low
Application Fields
Industrial
Certification
ISO, CE, CCC, CTI
Condition
New
Flow Rate
6m3/H - 500m3/H
Air Flow
8300m3/H - 480000m3/H
Air Intake Type
Bottom Intake
Spray Pump
Siemens Motor(IP55 F Grade)
Fan
Aluminum Alloy Axial Flow Type
Housing Material
Al-Zn Alloy Steel(SUS304 Optional)
Coil Tube
SUS304 (Copper Optional)
Fan Blade
Aluminum Alloy
Heat Exchange Layer
PVC Filler
Optioanl Parts
PLC Control Cabinet, Buffer Tank, Process Pump
Voltage
380V-3pH-50Hz (Customizable)
Trademark
COOLINGFUN
Transport Package
in Bulk
Specification
30 - 100 Tons
Origin
China
HS Code
8418699090

Product Description

CTI Certificated Counter Flow Cloosed Cooling Water Tower for Screw Chiller


BRIEF DESCRIPTION

  Closed Cooling Tower (also called "Evaporative Air Cooler") adopt a combination technology of secondary heat exchange coil tube (air and water flow in the same direction, mixed-flow type) and PVC filler, to achieve high-efficient heat-exchange effect. Since air and spray water flow through the coil in the same direction, the spray water can cover the coil tube surface to the greatest extent to make sure its surface is completely wet. Compared to the structure that air and water flow in the counter direction, same direction flow structure can greatly reduce the formation of dry spots and water scale on the coil tube wall.

  Both of fans and pumps adopt high quality bearings without other wear-out parts, direct-connecting type structure help to bring down the noise and failure rate, avoid the rotational loss. Different structure designs give more choice for different application fields.


STRUCTURE AND MAIN MATERIALS 

TECHNICAL SPECIFICATIONS
 
Model
GBN-
Flow RateFanSpray PumpWater Pipe (DN)Overall DimensionWeight
PowerAir FlowPowerWater FlowInletOutletLWHJN.W.R.W.
m3/hKWm3/hKWm3/hmmmmmmmmmmmmKGKG
6T60.55*183000.552065*165*1110010002300300450650
10T100.75*1125000.552065*165*1125012502600300550820
15T151.1*1155000.752365*165*1150012502900300630950
20T201.5*1180000.752365*165*1150015002900300680990
25T250.75*2250000.752365*165*11900150029003008501520
30T301.1*2310000.752380*180*12250150029003009301650
40T401.5*2360001.13680*180*126501500300030010601960
50T502.2*2500001.15380*180*128001600300030011202080
60T603*1160001.153100*1100*123502000310030012201850
70T704*1600001.570100*1100*128502000310030013501850
80T805.5*1650001.570125*1125*130002200320030017502050
90T905.5*1750002.284125*1125*130002350320030019803880
100T1007.5*1900002.284125*1125*131002450320030021804270
125TD1255.5*2110003120150*1150*135002300380030027005370
150TD1505.5*2130003120100*2100*240002450380030032507980
175TD1757.5*2170004150125*2125*242002900380030038009300
200TD2007.5*2180004180125*2125*2510030003800300426011000
225TD2255.5*31950002.2*2100*2125*2125*2600027004050300538012370
250TD2505.5*32150003*2120*2125*2125*2630028004050400595013980
275TD2755.5*32150003*2120*2150*2150*2690029004050400645014350
300TD3007.5*33000003*2150*2150*2150*2720030004050400732015680
350TD3505.5*43400003*2150*2125*4125*4840031504300400102501850
400TD4007.5*44000004*2180*2125*4125*4900031504300400112501850
450TD4507.5*44200004*2180*2150*4150*4960032004300400119602050
500TD50011*34800005.5*2233*2150*4150*41020032504300400127603880
REMARK: 1. Design Conditions: Hot Water(inlet water) Temp.: T1=37ºC; Cold Water(outlet water) Temp.: T2=32ºC; Dry Bulb Temp.: TDB=31.8ºC; Wet Bulb Temp.: TWB=28ºC; Atmospheric Pressure: P=9.94x104Pa
2. Above tehcnical datas are for single set of cooling tower module, each model can be used alone or combined as needed.
3. The delivery lift of cooling tower is approximately equal to its height(H).


FEATURES AND MATERIALS

EXTERNAL DIMENSION DRAWINGS

PACKAGED UNIT WITH PROCESS PUMP AND BUFFER TANK
DETAILED DRAWING FOR EACH PROJECT
REMARK: To be convenient loaded inside the container, the completed and tested cooling tower will be divided into upper and bottom two parts, there're reserved install holes in the between-in U-steel for quick and easy assembly work at site.

TYPIC APPLICATION FIELDS
Other applications: Heat Pump, Generating Set, Glass Melting Pit, Boiler Steam Condenses, Power Plant, Chemicals, Food, Cold Room, Pharmaceutical Factory etc.

PROJECT CASES

WHY CHOOSE COOLINGFUN?
>>  You want experience…
Experienced R&D team bring more than 10 years of process cooling & heating experience with knowledgeable application, product and service specialists available to discuss your needs. 

>> You want someone who understands your process…
Provided with experience in a wide range of process cooling & heating industries. When you give us the chance, we will show the rich experience and get you the correct solution to your problems.

>> You want a product that fits your unique needs…
Offer a wide range of standard units, what's more, our application specialists can suggest the customized units to meet unique needs.

>> You want specialized control…
Build our own system controls from tailor made embedded micro-processor base products to PLC options. System control makes the difference in your process repeatability, efficiency and reliability.

>> You want professional design manufacturer…
We specialize in industrial fluid process temperature control fields, and provide the complete systems solutions.

>> You want energy efficient solutions…
Our specialists are aware of the rising cost of energy and the pressure to reduce energy consumption and we offer many energy saving products that favor lifetime costs.

>> Our Warranty
All the products are passed strict test, and COOLINGFUN provide 15 months guarantee since the date of bill of lading. During this guarantee period, COOLINGFUN provide spare parts without any charge in case of quality discrepancy caused by us. If out of guarantee period, we still can charge the buyer cost price of spare parts and provide Technical Product support for customers.

>> Our Service:

- OEM & ODM, or any other unique customized demands are acceptable.
- Any price inquiries or technical inquiries will be responded within 24 hours.
- Experienced technical engineers will give the model selection guide or help design the customized model.
- Detailed quotation scheme and system configuration will be provided to the customer together.
- The whole order process is tracked throughout:  
  Technical proposal communication → Order production → Performance test → Packaging→ Necessary documents confirmation → Transportation → Customs declaration → Shipping
   → Installation assistance(provide user manual or install video) → After-sales support.
Buyer will receive the notification mail (include photos,  report or other documents) in each process.
- Besides the temperature control units, other install parts or auxiliary equipments is optional according to customers' requirements.
- All necessary installation documentation (e.g. Electrical diagram, User Manual) will be provided in both electronic copy and hard copy.
- Perfect after-sales service system, it's including: Technical guidance, detailed machine maintenance methods, troubleshooting solutions, regular return visit etc.

 